Chapter 10: Configurations
151
Triangle Configuration
The following procedure must be followed to ensure this configuration
functions properly.
After re-connection, all Paragon switches must undergo a FUNC reset to
clear the switches' database. See Reset Unit (on page 43) for more
information o
n clearing the database. This procedure should be performed
starting from the third-tier device down to the Base Unit.
Execute the FUNC reset in the following order: UMT-3 --> UMT-2 -->
UMT-1.
Important: In the triangle configuration, you must sort the channels by
name, or there are problems accessing channels. See
Selecting a Server
(on page 63).
Diamond Configurations
Single diamond configuration:
A user configured on the second tier and connected to UMT-2A has
access only to UMT-3A, while a user connected to UMT-2B can access
both UMT-3A and UMT-3B. The Base Unit (UMT-1) administrator has
access to all Paragon switches in the single diamond configuration.
The following procedure must be followed to ensure this configuration
functions properly.
After re-connection, all Paragon switches must undergo a FUNC
reset to clear the switches' database. See Reset Unit (on page 43)
for more information on
cle
aring the database. This procedure
should be performed starting from the third-tier device down to the
Base Unit.
Vue de la page 172